| HP ProCurve 2520-8-PoE Switch (J9137A) | HP ProCurve 2520-24-PoE Switch (J9138A) | HP ProCurve 2520G-8-PoE Switch (J9298A) |
|---|
| Ports |
| 8 RJ-45 auto-sensing 10/100 PoE ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3af PoE)
Media Type: Auto-MDIX
Duplex: half or full
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a SFP slot (for use with SFP transceivers)
1 RJ-45 serial console port
| 24 RJ-45 auto-sensing 10/100 PoE ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3af PoE)
Media Type: Auto-MDIX
Duplex: half or full
2 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a SFP slot (for use with SFP transceivers)
1 RJ-45 serial console port
| 8 RJ-45 auto-sensing 10/100/1000 PoE ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T, IEEE 802.3af PoE)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a SFP slot (for use with SFP transceivers)
1 RJ-45 serial console port
|
| Physical characteristics |
| Dimensions | 6.28(d) x 10(w) x 1.75(h) in. (15.95 x 25.4 x 4.45 cm) (1U height) | 9.69(d) x 17.44(w) x 1.75(h) in. (24.61 x 44.3 x 4.45 cm) (1U height) | 6.28(d) x 10(w) x 1.75(h) in. (15.95 x 25.4 x 4.45 cm) (1U height) |
| Weight | 3.62 lb. (1.64 kg) including power adapter and power cord | 7.1 lb. (3.22 kg) | 3.66 lb. (1.66 kg) including power adapter and power cord |
| Memory and processor |
| Processor | Freescale PowerPC 8313 @ 266 MHz, 32 MB flash, 128 MB DDR2 SDRAM; packet buffer size: 384 KB dynamically allocated | Freescale PowerPC 8313 @ 266 MHz, 32 MB flash, 128 MB DDR2 SDRAM; packet buffer size: 384 KB dynamically allocated | Freescale PowerPC 8313 @ 266 MHz, 32 MB flash, 128 MB DDR2 SDRAM; packet buffer size: 512 KB dynamically allocated |
| Mounting |
| Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting
| Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting
| Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; wall mounting
|
| Performance |
| 100 Mb Latency | < 1.9 µs (LIFO 64-byte packets) | < 1.9 µs (LIFO 64-byte packets) | < 5.3 µs (LIFO 64-byte packets) |
| 1000 Mb Latency | < 1.5 µs (LIFO 64-byte packets) | < 1.5 µs (LIFO 64-byte packets) | < 2.7 µs (LIFO 64-byte packets) |
| Throughput | 4.1 million pps | 6.2 million pps | 14.8 million pps |
| Switching capacity | 5.6 Gbps | 12.8 Gbps | 20 Gbps |
| MAC address table size | 8,000 entries | 8,000 entries | 8,000 entries |
| Environment |
| Operating temperature | 32ºF to 113ºF (0ºC to 45ºC) | 32ºF to 113ºF (0ºC to 45ºC) | 32ºF to 113ºF (0ºC to 45ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) |
| Acoustic | Power: 0 dB, Pressure: 0 dB | Power: 27.9 dB, Pressure: 36.0 dB; DIN 45635T.19 per ISO 7779 | Power: 0 dB, Pressure: 0 dB |
| Electrical characteristics |
| Description | Use only the external power adapter module (5070-6082, PA1 AC adapter) supplied with this product | | Use only the external power adapter module (5070-6082, PA1 AC adapter) supplied with this product |
| Maximum heat dissipation | 87 BTU/hr (91.79 kJ/hr) | 208 BTU/hr (219.44 kJ/hr) | 89 BTU/hr (93.9 kJ/hr) |
| Voltage | 100-240 VAC | 100-127 / 200-240 VAC | 100-240 VAC |
| Current | 1.5 A | 3.3 / 1.6 A | 1.5 A |
| Idle power | 9.4 W | 21.6 W | 9.3 W |
| Maximum power rating | 85.5 W | 257 W | 86.2 W |
| PoE power | 67 W | 195 W | 67 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the total power budget available to all PoE ports. | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the total power budget available to all PoE ports. | Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. PoE Power is the total power budget available to all PoE ports. |
| Safety |
| cUL (CSA 22.2 No. 60950) CE Labeled UL 60950-1 UL Listed CAN/CSA 22.2 No. 60950 EN 60825 AS/NZS 60950 IEC 60950-1 EN 60950-1
| cUL (CSA 22.2 No. 60950) CE Labeled UL 60950-1 UL Listed CAN/CSA 22.2 No. 60950 EN 60825 AS/NZS 60950 IEC 60950-1 EN 60950-1
| cUL (CSA 22.2 No. 60950) CE Labeled UL 60950-1 UL Listed CAN/CSA 22.2 No. 60950 EN 60825 AS/NZS 60950 IEC 60950-1 EN 60950-1
|
| Notes |
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, for example, J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, for example, J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, for example, J4858B, J4859C) are required.
|